Air
P611 Handheld Laser Particle Counter
Airy Technology Handheld Laser Particle Counter MODEL P611
Airy Technology P611 is the accurate, user friendly handheld particle counter. Its large color display shows 6 channels of cumulative and different particle counts simultaneously. Airy Technology P611 saves up to 10,000 sample data in the memory, which can be reviewed on the unit display and/or easily downloaded to your PC via USB cable. Temperature and humidity can also be monitored with the optional probe. P611 complies with ISO 21501-4 and comes with a two-year warranty. With excellent quality and reliable performance, Airy Technology P611 is the best solution for professionals who validate ISO cleanrooms (Class 5-9) and investigate indoor air quality.
Applications:
- ISO Cleanroom Certification (ISO Class 5-9)
- Point Measurements at Cleanrooms
- Particle Source Investigation
- Filter Testing and Leak Detection
- Indoor Air Quality Investigations
- Quality Control
Features:
- 6-Channel Simultaneous Measurements
- Channel Range 0.3-10.0µm
- Flow Rate : 0.1CFM (2.83 LPM)
- Optional Temperature & Humidity Probe
- Large Color Display
- Maximum Concentration: 4,000,000 particles / ft3
- Data Download Software Included
- Buffer Memory: 10,000 Records
- ISO 21501-4 and JIS B9921 Compliant
Included Accessories:
Operating manual on CD, Quick guide, AC adapter, Isokinetic inlet, Probe for tubing, USB cable, Zero filter, Software, 4 x AA batteries with charger, Calibration certificate, Carrying case.
Optional Accessories:
Temperature/Humidity probe
P311 Handheld Laser Particle Counter (3 Channel)
Airy Technology Handheld Laser Particle Counter MODEL P311
Airy Technology P311’s large color display shows cumulative and differential particle counts of 3 particle sizes simultaneously, Channel 1 and channel 2 can easily be changed by a user. P311’s maximum concentration of 4,000,000 particles/ft3 and up to 8,000 data set record capabilities is the highest in the market. Data can be checked on the unit display and/or easily downloaded to your PC via USB cable and saved as a CVS file which is transferable to Excel. P311 is accurate, dependable, user friendly, compact and light weight.
Applications:
- ISO Cleanroom Certification (ISO Class 4>)
- Point Measurements at Cleanrooms
- Particle Source Investigation
- Filter Testing
- Indoor Air Quality Investigations
- Quality Control
Features:
- Three Channel Particle Counter
Channel 1: 0.3/0.5 µm (Selectable)
Channel 2: 0.5/1.0/2.0/2.5 µm (Selectable)
Channel 3: 5.0 µm
- Large Color Display
- Cumulative and Differential Count
- Maximum Concentration: 4,000,000 particles / ft3
- Data Download Software Included
- USB for Data Download
- Buffer Memory: 8,000 Records
- View Saved Data on the Display
- Measure by Count, /m3, or / ft3
Included Accessories:
AC Adaptor, Isokinetic Inlet, USB Cable, Zero Filter, Software, 4 x AA Batteries with Charger,
Calibration Certificate, Quick Guide, Operating Manual on CD, Carrying Case
LV100 Vane probe thermo-anemometer
Vane probe thermo-anemometer
LV 101 – Vane probe Ø 14 mm – Fixed probe
LV 107 – Vane probe Ø 70 mm – Fixed probe
LV 110 – Vane probe Ø 100 mm – Fixed probe
Functions
- Air velocity and ambient temperature
- Selection of units
- HOLD function
- Minimum and maximum values
- Automatic average
- Airflow calculation
- Airflow calculation with cone
- Adjustable automatic shut-off
- Adjustable backlight
- Detection of flow direction (LV107 - LV 110)
Technical Details
Measuring elements.................Vane anemometer :
LV101 : Proximity sensor
LV107/110 : Hall effect sensor
Ambient temperature : Pt100 class A
Display.................... ..................2 lines, LCD technology. Sizes 50 x 34.9 mm.
1 line of 5 digits with 7 segments (value)
1 line of 5 digits with 16 segments (unit)
Housing................................. ....Shock-proof made of ABS, IP54 protection
Keypad......................... .............Metal-coated with 5 keys
Cable......................... ................straight, lg. 200 mm (LV101)
retractable, length 450 mm, up to 2.4 m when released
Conformity..................... ...........electromagnetical compatibility (NF EN 61326-1 guideline)
Power supply.................... ........1 alcaline battery 9V 6LR61
Operating temperature (instrument)..from 0 to 50°C
Operating temperature (probe).......from -20 to +80°C
Storage temperature................from -20 to +80°C
Auto shut-off....................... ......adjustable from 0 to 120 min
Weight.......................... .............190g
Languages................................French, english
AQ100 Air Quality Meter
Air Quality Meter
Functions
- CO2 measurement and ambient temperature
- Selection of units
- Minimum and maximum values
- HOLD function
- Adjustable automatic shut-off
- Adjustable backlight
Technical Features
Measuring element...................CO2 : Infrared sensor.
(Non dispersive- infrared sensor NDIR)
Ambient temperature : Pt100 class A
Display......................................2 lines, LCD technology. Sizes 50 x 34.9 mm.
1 line of 5 digits with 7 segments (value)
1 line of 5 digits with 16 segments (unit)
Housing.....................................Shock-proof made of ABS, IP54 protection
Keypad......................................Metal-coated with 5 keys
Cable.........................................retractable, length 450 mm, up to 2.4 m when
released
Conformity................................electromagnetical compatibility (NF EN 61326-1 guideline)
Power supply............................1 alcaline battery 9V 6LR61
Operating temperature.............from 0 to 50°C
Storage temperature................from -20 to +80°C
Auto shut-off.............................adjustable from 0 to 120 min
Weight.......................................190g
Languages................................French, english
CTV200 Air Velocity / Airflow Transmitter
Air Velocity / Airflow Transmitter
• Ranges from 0-1 m/s to 0-20 m/s (configurable) and 0-50 °C
• Configurable intermediate ranges
• Airflow function
• Simultaneous display of 2 parameters
• 2 outputs 4-20 mA or 0-10V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer) alarms
• Output diagnostics
• ABS IP 65 housing, with or without 2-line backlit display
• Quick and easy mounting using the “1/4 turn” system with wall-mounting plate.
Air Velocity
Measuring range ..................0-1 m/s to 0-20 m/s
Units of measurement .........m/s, fpm
Accuracy * ............................from 0 to 3 m/s : ±3% of reading ±0,03 m/s
from 3 to 20 m/s : ±3% of reading ±0,1 m/s
Response time .....................1/e (63%) 4 sec.
Resolution ............................from 0 to 3 m/s : 0,01m/s
3 to 20 m/s : 0,1 m/s
Type of fluid..........................air and neutral filtered gases
Temperature
Measuring range...................................0 to +50°C
Units of measurement .......................°C, °F
Accuracy * ..........................................±0,5% of reading ±0,3°C
Response time ................................... t0,9 = 9 sec. for Vair = 1 m/s
Resolution ..........................................0,1°C
Type of sensor....................................Pt100 class A as per DIN IEC751
Type of fluid........................................air and neutral gases
CTV100 Temperature and air velocity transmitter
Temperature and air velocity transmitter
• Temperature and air velocity transmitter type CTV100.
• Ranges from 0-5 m/s to 0-30 m/s and 0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to
+100°C (see "Configuration")
• 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires)
• ABS IP 65 housing, with or without display
• Alternating display of air velocity and temperature
• Quick and easy mounting “1/4 turn” system with wall-mount plate
Air Velocity
Measuring range ..................0 to 5m/s,0 to 10m/s, 0 to 15m/s, 0 to 20m/s, 0 to 30m/s
Units of measurement .........m/s and fpm
Accuracy * ............................±3% of reading ±0,3 m/s
Response time .....................1/e (63%) 2 sec.
Resolution ............................0,1 m/s
Type of fluid..........................air and neutral gases
Temperature
Measuring range...................................0 to +50°C, -20 to +80°C,-50 to +50°C,0 to +100°C
Units of measurement .......................°C, °F
Accuracy * ..........................................±0,5% of reading ±0,4°C
Response time ...................................1/e (63%) 5 sec.
Resolution ..........................................0,1°C
Type of sensor....................................Pt100 class A as per DIN IEC751
Type of fluid........................................air and neutral gases
AMI300 Multi Function Portable Instrument
Multi Function Portable Instrument
Class 300 Instrument
6 instruments in 1 device !
- Thermometer
- Manometer
- Hygrometer
- Anemometer
- Air Quality
- Tachometer
Detailed functions :
- Anemometer
Select hotwire, duct or K factor, airflow, automatic average, point/point average, automatic point/point average, hold, min/max values, standard deviation, K2 factor, storage.
- Thermometer
Pt100 : Delta T (2 channels), choice of units (°C, °F), hold function, min/max values, storage.
Thermocouple : Delta T (2 channels), choice of units (°C, °F), hold function, min/max values, storage.
- Manometer
Pressure : Automatic (MP200P) or manual self calibration (MP200 M, MP200 G), select units, pressure integration (0 to 9), point / point average, automatic point / point average, automatic average, hold, min/max values, standard deviation, storage.
- Velocity : select Pitot tube or Debimo or coefficient for others sensing elements, select duct, select units, point / point average, automatic point / point average, automatic average, temperature balancing (manual and automatic), manual air pressure balancing, K2 factor, hold, min/max values, standard deviation, storage.
- Hygrometry: Select units, hold, min/max values, storage.
- Psychrometer : dew point, wet temperature, enthalpy, absolute humidity, hold, min/max values, storage.
- Surface dew point : for contact temperature probe. Hold, min/max values, storage.
WBGT index : for hygrometry proble used with black ball. Index calculation for inside and outside, storage.
- Current / voltage:
Adjustable scale, hold, min/max values, storage.
Measuring units :
- Pressure : Pa, mmH2O, mbar, hPa, In wg, mmHg, DaPa
- Velocity : m/s, fpm, Km/h, mph
- Hygrometer : %HR
- Psychrometer : °Ctd, °Ftd, Kj/Kg, g/Kg
- Airflow : m³/h, cfm, l/s, m³/s
- Temperature : °C, °F
- Current/voltage : V, mA
- CO/CO2 : ppm
VT200 Thermo-Anemometer
Thermo-Anemometer
Class 200 Instrument
- Interchangeable measurement modules
- User-friendly (Joystick navigation)
- Large graphic display
- Blue backlight
- Up to 8,000 measurement points
- Up to 6 measurements simultaneously
- Instrument/PC wireless communication
Interchangeable measurement modules
1 instrument = more than 1 range
and 1 parameter available.
Wireless connection
Instrument / PC
Instrument / Probe
Smart-plus system
Probes automatically recognized when connected to the instrument.
VT 200 F – Current/voltage module – Standard hotwire
VT 200 TF – Current/voltage module – Telescopic gooseneck-shaped hotwire
VT 200 H – Current/voltage module – Ø 70 mm vane probe
VT 200 L – Current/voltage module – Ø 100 mm vane probe
VT 200 P – Current/voltage module – Ø 14 mm vane probe
VT 200 TP – Current/voltage module –Telescopic Ø 14 mm vane probe
MP200 Thermo-Anemo-Manometer
Thermo-Anemo-Manometer
Class 200 Instrument
- Interchangeable measurement modules
- User-friendly (Joystick navigation)
- Large graphic display
- Blue backlight
- Up to 8,000 measurement points
- Up to 6 measurements simultaneously
- Instrument/PC wireless communication
Interchangeable measurement modules
1 instrument = more than 1 range and 1 parameter available.
Wireless connection
Instrument / PC
Smart-plus system
Probes automatically recognized when connected to the instrument.
Modules/Probes For:
Pressure
Air Velocity
Air Flow
Thermocouple
Current
Voltage
CO
MP 200 P – ± 500 Pa
MP 200 M – ± 2500 Pa
MP 200 G – ± 10,000 Pa
MP 200 H – ± 500 mBar
MP 200 HG – ± 2000 mBar
AQ200 Air Flow Meter
Air Flow Meter
Class 200 Meter
- Interchangeable measurement modules
- User-friendly (Joystick navigation)
- Large graphic display
- Blue backlight
- Up to 8,000 measurement points
- Up to 6 measurements simultaneously
- Instrument/PC wireless communication
- Wireless probes
Connections:
Interchangeables measurement modules
1 instrument = more than 1 range and 1 parameter available.
Wireless connection
Instrument / PC
Instrument / probe
Smart-plus system
Wireless or wired probes automatically recognized when connected to the instrument.
AQ 200 – Current voltage module – CO2/Temp. probe
AQ 200P – Current voltage module – CO2/Temp./Hygrometry probe
VT100 Hotwire thermo-anemometer
Hotwire thermo-anemometer
Functions
- Air velocity and ambient temperature
- Selection of units
- HOLD function
- Minimum and maximum values
-Automatic average
- Air flow calculation
- Adjustable automatic shut-off
- Adjustable backlight
Measuring element...................Hotwire air velocity : Thermistance with a
negative temperature coefficient.
Ambient temperature : Pt100 1/3 DIN
Display......................................2 lines, LCD technology. Sizes 50 x 34.9 mm.
1 line of 5 digits with 7 segments (value)
1 line of 5 digits with 16 segments (unit)
Housing.....................................Shock-proof made of ABS, IP54 protection
Keypad......................................Metal-coated with 5 keys
Cable.........................................Straight, lg. 2 m
Conformity................................electromagnetical compatibility (NF EN 61326-1 guideline)
Power supply............................1 alcaline battery 9V 6LR61
Operating temperature.............from 0 to 50°C
Storage temperature................from -20 to +80°C
Auto shut-off.............................adjustable from 0 to 120 min
Weight.......................................190g
Languages................................French, English