Transmitters
CTV200 Air Velocity / Airflow Transmitter
Air Velocity / Airflow Transmitter
• Ranges from 0-1 m/s to 0-20 m/s (configurable) and 0-50 °C
• Configurable intermediate ranges
• Airflow function
• Simultaneous display of 2 parameters
• 2 outputs 4-20 mA or 0-10V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer) alarms
• Output diagnostics
• ABS IP 65 housing, with or without 2-line backlit display
• Quick and easy mounting using the “1/4 turn” system with wall-mounting plate.
Air Velocity
Measuring range ..................0-1 m/s to 0-20 m/s
Units of measurement .........m/s, fpm
Accuracy * ............................from 0 to 3 m/s : ±3% of reading ±0,03 m/s
from 3 to 20 m/s : ±3% of reading ±0,1 m/s
Response time .....................1/e (63%) 4 sec.
Resolution ............................from 0 to 3 m/s : 0,01m/s
3 to 20 m/s : 0,1 m/s
Type of fluid..........................air and neutral filtered gases
Temperature
Measuring range...................................0 to +50°C
Units of measurement .......................°C, °F
Accuracy * ..........................................±0,5% of reading ±0,3°C
Response time ................................... t0,9 = 9 sec. for Vair = 1 m/s
Resolution ..........................................0,1°C
Type of sensor....................................Pt100 class A as per DIN IEC751
Type of fluid........................................air and neutral gases
CTV100 Temperature and air velocity transmitter
Temperature and air velocity transmitter
• Temperature and air velocity transmitter type CTV100.
• Ranges from 0-5 m/s to 0-30 m/s and 0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to
+100°C (see "Configuration")
• 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires)
• ABS IP 65 housing, with or without display
• Alternating display of air velocity and temperature
• Quick and easy mounting “1/4 turn” system with wall-mount plate
Air Velocity
Measuring range ..................0 to 5m/s,0 to 10m/s, 0 to 15m/s, 0 to 20m/s, 0 to 30m/s
Units of measurement .........m/s and fpm
Accuracy * ............................±3% of reading ±0,3 m/s
Response time .....................1/e (63%) 2 sec.
Resolution ............................0,1 m/s
Type of fluid..........................air and neutral gases
Temperature
Measuring range...................................0 to +50°C, -20 to +80°C,-50 to +50°C,0 to +100°C
Units of measurement .......................°C, °F
Accuracy * ..........................................±0,5% of reading ±0,4°C
Response time ...................................1/e (63%) 5 sec.
Resolution ..........................................0,1°C
Type of sensor....................................Pt100 class A as per DIN IEC751
Type of fluid........................................air and neutral gases