PJ Boner Automation Services
Calibration, Weighing & Instrumentation Specialists Ireland

Differential pressure transmitter

Type 401 OEM Relative and Differential Pressure Transmitter

OEM Relative and differential pressure transmitter Type 401
0 … 3 – 5 mbar

The type 401 series pressure transmitters, with its unique proven ceramic lever technology, has adjusted, temperature-compensated sensor signals, available as a voltage output.

Additional DescriptionMore Details

The (VDC) voltage output is an amplified, linear signal suitable for direct processing in electronic control systems.

Fixed order quantities on request


€0.00Price:
Loading Updating cart…

Type 402 Relative and differential pressure transmitter

Relative and differential pressure transmitter Type 402
0 … 3 – 50 mbar

The pressure transmitters of type 402 with their proven ceramic fulcrum lever technology have adjusted, temperature-compensated sensor signals that are available with voltage outputs.

Additional DescriptionMore Details

They are ideally suited for registering fine air flow in air conditioning technology and for measuring fine pressures in the environmental / medical technology sectors.

Pressure ranges
0 … + 3 mbar
0 … + 5 mbar
0 … + 10 mbar
0 … + 30 mbar
0 … + 50 mbar


€0.00Price:
Loading Updating cart…

Type 663 Relative, absolute and differential pressure transmitter

Relative, absolute and differential pressure transmitter Type 663
- 5 … + 5 – 2000 mbar

The pressure transmitter of product range type 663 have calibrated and temperature compensated sensor signals which are available as voltage output.

Additional DescriptionMore Details

The amplified linear voltage output signal, can be connected directly into an electronic control system. The transmitter can be mounted directly due a pcb board or with a 2.5 mm plug connection.

Pressure ranges
– 5 … + 5 mbar
0 … + 5 mbar
0 … + 10 mbar
0 … + 20 mbar
0 … + 50 mbar
0 … + 100 mbar
0 … + 200 mbar
0 … + 0.5 bar
0 … + 1 bar
0 … + 2 bar
800 … + 1200 mbar


€0.00Price:
Loading Updating cart…

Type 694 Relative and differential pressure transmitter

Relative and differential pressure transmitter Type 694
-0.5 … 0.5 – 50 mbar

The pressure transmitters of the Type 694 series incorporate a proved ceramic fulcrum lever technology.

Additional DescriptionMore Details

They deliver adjusted temperature-compensated sensor signals, available as standard voltage or current outputs. They are ideal for registering low air flow in air conditioning systems and for the measurement of fine pressures in environmental, laboratory and cleanroom applications (air and non-corrosive gases).

Pressure ranges
- 0.5 … + 0.5 mbar
0 … + 1 mbar
0 … + 3 mbar
0 … + 5 mbar
0 … + 10 mbar
0 … + 16 mbar
0 … + 25 mbar
0 … + 50 mbar


€0.00Price:
Loading Updating cart…

Type 698 Relative and differential pressure module

Relative and differential pressure module with or without display Type 698
0 … 1 mbar – 6 bar

The relative and differential pressure modules type 698 are suitable for monitoring pressure and flow in air conditioning systems and in the laboratory sector.

Additional DescriptionMore Details

The modules are selectively available with two limit switches, display, square root extraction and standardised output signals. The built in pressure transmitters are our proven types 516, 402 or 663, depending on the pressure range.

Pressure ranges
– 5.00 … + 5.00 mbar Differential pressure
– 0.50 … + 0.50 mbar Differential pressure
– 0.50 … + 1.00 mbar Differential pressure
– 0.50 … + 3.00 mbar Differential pressure
– 0.50 … + 5.00 mbar Differential pressure
0.00 … + 1.00 mbar Differential pressure
0.00 … + 3.00 mbar Differential pressure
0.00 … + 5.00 mbar Differential pressure
0.0 … + 10.0 mbar Differential pressure
0.0 … + 30.0 mbar Differential pressure
0.0 … + 50.0 mbar Differential pressure
0 … + 100 mbar Differential pressure
0 … + 200 mbar Differential pressure
0 … + 500 mbar Differential pressure
– 1.00 … + 0.00 bar Relative pressure
0.00 … + 1.00 bar Relative pressure
0.00 … + 1.60 bar Relative pressure
0.00 … + 2.50 bar Relative pressure
0.00 … + 4.00 bar Relative pressure
0.00 … + 6.00 bar Relative pressure


€0.00Price:
Loading Updating cart…

Type 403 Relative and differential pressure transmitter

Relative and differential pressure transmitter Type 403
0 … 3 – 8 mbar

The pressure transmitters of type 403 are outlined for the optimization of calorific values in gas fired heating systems.

Additional DescriptionMore Details

All materials used are compatible with burnable gas. In combination with the differential pressure transmitter type 401 a electronic airgas-compound can be realized. The type 403 series pressure transmitters, with its unique proven ceramic lever technology, has adjusted, temperature-compensated sensor signals, available as a voltage output. The (VDC) voltage output is an amplified, linear signal suitable for direct processing in electronic control systems.

Fixed order quantities on request


€0.00Price:
Loading Updating cart…

Type 652 Relative and differential pressure transmitter

Relative and differential pressure transmitter Type 652
0 … 50 – 1000 mbar

The pressure transmitter of type series 652 are used for the long- and shortdistance transmission of electrical pressure-proportional signals.

Additional DescriptionMore Details

They are specially suited for the continuous level or flow monitoring of neutral and slightly aggressive liquids and gases in heating, ventilation and process technology. The pressure or differential pressure to be monitored acts on a diaphragm, which in turn acts against a spring. As a result of the pressure action and the resultant diaphragm movement a permanent magnet fastened on the diaphragm moves in the direction of a hall sensor arranged outside the pressure case. This sensor emits an electrical signal which is proportional to the magnetic field. The signal is linearized, compensated and amplified.

Pressure ranges
0 … + 50 mbar
0 … + 100 mbar
0 … + 200 mbar
0 … + 500 mbar
0 … + 1000 mbar


€0.00Price:
Loading Updating cart…

Type 692 Relative and differential pressure transmitter

Type 692
0 … 0.1 – 25 bar

The pressure transmitter of type series 692 with proven, unique ceramic technology, features adjusted and amplified sensor signals which are available as standardised voltage or current outputs.

Additional DescriptionMore Details

Various application-specific pressure and electrical connections and housing materials suitable for different media can be provided.

Pressure ranges
0 … + 0.1 bar
0 … + 0.2 bar
0 … + 0.25 bar
0 … + 0.3 bar
0 … + 0.4 bar
0 … + 0.5 bar
0 … + 0.6 bar
0 … + 1 bar
0 … + 1.6 bar
0 … + 2.5 bar
0 … + 4 bar
0 … + 6 bar
0 … + 10 bar
0 … + 16 bar
0 … + 25 bar


€0.00Price:
Loading Updating cart…

CP110 Pressure sensor

CP110 Pressure sensor

KEY POINTS

- Ranges from -100/+100 Pa to -10000/+10000 Pa (according to models)
- Configurable intermediary ranges
- 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires) or 4-20 mA
output, passive loop, power supply from 16 to 30 Vdc (2 wires)
- ABS V0 housing, IP65, with or without display
- “¼ turn” system mounting with wall-mount plate
- Housing with simplified mounting system
- Solenoid valve for auto-calibration (only on CP111 model)

Material : ABS V0 as per UL94
Protection : IP65
Display : LCD 10 digits. Size : 50 x 17 mm
Height of digits : Value : 10 mm ; Unit : 5 mm
Connections : ribbed, Ø 6.2 mm
Cable gland : for cables Ø 8 mm maximum
Weight : 143 g

Additional DescriptionMore Details

TECHNICAL FEATURES
Measurement units Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
Accuracy* CP111 : ±1% of reading ±2 Pa ; CP112 : ±1.5% of reading ±3 Pa ; CP113 : ±1.5% of reading ±3 mmH2O
Response time 1/e (63%) 0.3 s
Resolution 1 Pa ; 0.1 mmH2O ; 0.01 mbar ; 0.01 inWG ; 0.01 mmHG ; 0.1 daPa ; 0.001 kPa
Autozero Manual with push-button ; Automatic by solenoid valve (only on CP111 model)
Type of fluid Air and neutral gases
Overpressure tolerated CP111/112 : 21 000 Pa – CP113 : 69 000 Pa
Operating temperature From 0 to +50 °C
Storage temperature From -10 to +70 °C

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

CP116 Atmospheric pressure sensor

CP116 Atmospheric pressure sensor

KEY POINTS

- Ranges from -100/+100 Pa to -10000/+10000 Pa (according to models)
- Configurable intermediary ranges
- 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires) or 4-20 mA
output, passive loop, power supply from 16 to 30 Vdc (2 wires)
- ABS V0 housing, IP65, with or without display
- “¼ turn” system mounting with wall-mount plate
- Housing with simplified mounting system
- Solenoid valve for auto-calibration (only on CP111 model)

Material : ABS V0 as per UL94
Protection : IP65
Display : LCD 10 digits. Size : 50 x 17 mm
Height of digits : Value : 10 mm ; Unit : 5 mm
Connections : ribbed, Ø 6.2 mm
Cable gland : for cables Ø 8 mm maximum
Weight : 143 g

Additional DescriptionMore Details

TECHNICAL FEATURES
Measurement units Pa, mmH2O, inWG, mmHG, daPa, kPa, hPa, mbar
Accuracy* CP111 : ±1% of reading ±2 Pa ; CP112 : ±1.5% of reading ±3 Pa ; CP113 : ±1.5% of reading ±3 mmH2O
Response time 1/e (63%) 0.3 s
Resolution 1 Pa ; 0.1 mmH2O ; 0.01 mbar ; 0.01 inWG ; 0.01 mmHG ; 0.1 daPa ; 0.001 kPa
Autozero Manual with push-button ; Automatic by solenoid valve (only on CP111 model)
Type of fluid Air and neutral gases
Overpressure tolerated CP111/112 : 21 000 Pa – CP113 : 69 000 Pa
Operating temperature From 0 to +50 °C
Storage temperature From -10 to +70 °C

Download Product Data Sheet


€0.00Price:
Loading Updating cart…
Page 1 of 212
LoadingUpdating…

Copyright © 2014 P.J.Bonner