PD663 ProtEX Lite 3½+ Digit Explosion-Proof Loop-Powered Meter
PD663 ProtEX Lite 3½+ Digit Explosion-Proof Loop-Powered Meter
The PD663 is a rugged, explosion-proof NEMA 4X loop-powered meter perfect for applications where a simple, inexpensive display is required in a hazardous area.
The PD663 derives all its power from the 4-20 mA loop. The PD663 is scaled using four push buttons and can be done without applying an actual calibration signal, and through the explosion-proof enclosure with optional magnetic reed switches and a magnet key. The PD663’s display will read up to 2999; we call this 3½+ digits! The loop-powered backlighting option lets you see the display under any lighting condition and is powered completely from the 4-20 mA loop. This means there is no need for additional wiring and never any batteries to change.
The PD663 is housed in a rugged, explosion-proof, cast aluminum, NEMA 4X enclosure and is provided with two threaded conduit holes and integrated pipe or wall mounting flanges.
General:
Display: 0.6" (15.24 mm) LCD, 3½+ digits; -1999 to 2999
Display Update Rate: 2 Updates/Second
Display Orientation: Display may be mounted at 90° increments up to 270° from default orientation.
Over-Range: Display Flashes 2999
Under-Range: Display Flashes -1999
Programming Method: 4 Front Panel Pushbuttons (behind glass). Magnet may also be used for programming; P/N PDA-MAG.
Noise Filter: Programmable HI, LOW, or OFF
Recalibration: Recalibration is recommended at least every 12 months.
Max/Min Display: Max/Min readings reached by the process are stored until reset by the user or until power to the meter is turned off.
Non-Volatile Memory: All programmed settings are stored in non-volatile memory for a minimum of ten years if power is lost.
Normal Mode Rejection: 64 dB at 50/60 Hz
Operating Temperature: -40 to 75°C
Storage Temperature: -40 to 75°C
Relative Humidity: 0 to 90% non-condensing
Connections: Removable screw terminals accept 12 to 22 AWG
Tightening Torque: Screw terminal connectors: 4.5 lb-in (0.5 Nm)
Enclosure: Explosion-proof cast aluminum with glass window, 0.30% max copper content, corrosion resistant powder coating, color: blue. NEMA 4X, IP68. Two ½" NPT threaded conduit openings. One ½" NPT nickel plated brass conduit plug with 10 mm hex key fitting installed.
Mounting: May be mounted directly to conduit. Two mounting holes for 1.5" pipe or wall mounting.
Weight: 40 oz (1.13 kg)
Overall Dimensions: 4.30" x 4.27" x 3.62" (109 mm x 108 mm x 92 mm) (W x H x D)
Warranty: 3 years parts & labor
PD6310 ProVu Pulse Input Batch Controller
PD6310 ProVu Pulse Input Batch Controller
Input: Pulse, open collector, NPN, PNP, TTL, switch contact,
sine wave (coil), square wave, Modbus PV (slave)
Display: Dual-line 6-digit, 0.60″ (15 mm) & 0.46″ (12 mm)
Case: Smooth die-cast aluminum explosion-proof
Power: 85-265 VAC or 12/24 VDC option
Operating Temperature: -40 to 65°C
BATCH CONTROL FEATURES
•Start/Pause/Stop, Change Batch with Front Buttons
•Display Batch Total, Rate, Grand Total, Count or Preset
•Single or Multi-Stage Batch Control (Up to 8 Relays)
•Automatic Overrun Correction
•Rate in Units per Second, Minute, Hour, or Day
•Automatic or Manual Batch Control
•Low or High Flow Alarms while Batching
•9 Digit Grand Total with Overflow Feature
•Count Up or Down with Each Batch
•Program and Control with a Computer
Using MeterView Pro
ADDITIONAL FEATURES
•PD6210: 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and
±10 V Inputs
•PD6310: Pulse, Open Collector, NPN, PNP, TTL, Switch
Contact, Sine Wave (Coil), Square Wave Inputs
•Large Dual-Line 6-Digit Display, 0.60" & 0.46"
•NEMA 4X, IP65 Front
•85-265 VAC or 12/24 VDC Input Power
•Sunlight Readable Display Models
•2 or 4 Relays + Isolated 4-20 mA Output Options
•External 4-Relay & Digital I/O Expansion Modules
•USB, RS-232, & RS-485 Modules for Modbus® RTU
PD6210 ProVu Analog Input Batch Controller
PD6210: ProVu Analog Input Batch Controller
Input: 0-20 mA, 4-20 mA; ±10 VDC (0-5, 1-5, 0-10 V); Modbus PV (slave)
Display: Dual-line 6-digit, 0.60″ (15 mm) & 0.46″ (12 mm)
Case: Smooth die-cast aluminum explosion-proof
Power: 85-265 VAC or 12/24 VDC option
Operating Temperature: -40 to 65°C
BATCH CONTROL FEATURES
•Start/Pause/Stop, Change Batch with Front Buttons
•Display Batch Total, Rate, Grand Total, Count or Preset
•Single or Multi-Stage Batch Control (Up to 8 Relays)
•Automatic Overrun Correction
•Rate in Units per Second, Minute, Hour, or Day
•Automatic or Manual Batch Control
•Low or High Flow Alarms while Batching
•9 Digit Grand Total with Overflow Feature
•Count Up or Down with Each Batch
•Program and Control with a Computer
Using MeterView Pro
ADDITIONAL FEATURES
•PD6210: 0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and
±10 V Inputs
•PD6310: Pulse, Open Collector, NPN, PNP, TTL, Switch
Contact, Sine Wave (Coil), Square Wave Inputs
•Large Dual-Line 6-Digit Display, 0.60" & 0.46"
•NEMA 4X, IP65 Front
•85-265 VAC or 12/24 VDC Input Power
•Sunlight Readable Display Models
•2 or 4 Relays + Isolated 4-20 mA Output Options
•External 4-Relay & Digital I/O Expansion Modules
•USB, RS-232, & RS-485 Modules for Modbus® RTU
PD6060 ProVu Dual Input Process Meter
PD6060: ProVu Dual Input Process Meter
Input: Dual 0-20 mA, 4-20 mA; ±10 VDC (0-5, 1-5, 0-10 V);
Modbus PV (slave)
Display:bDual-line 6-digit, 0.60″ (15 mm) & 0.46″ (12 mm)
Case: Smooth die-cast aluminum explosion-proof
Power: 85-265 VAC or 12/24 VDC option
Operating Temperature: -40 to 65°C
ADVANCED, VERSATILE, & CUSTOMIZABLE
The ProVu PD6060 meter combines two independently programmed analog inputs with powerful math functions to make an advanced meter capable of handling complex math requirements common in the process industry. Various math functions may be applied to the inputs including addition, difference, average, multiplication, division, ratio, and more. A customizable dual-line display allows a wide variety of input variables, math calculations, or units and tags to be displayed based on your application needs.
PD6060 KEY FEATURES
The ProVu PD6060 meter is the mathematician of the ProVu family. Its two process input channels and math functions make it unique while still maintaining all the great features of the ProVu family.
•Dual-Input Process Meter with Math Functions
•Addition, Difference, Average, Multiplication, Division, Min, Max, Weighted Average, Ratio, Concentration, & More
•0-20 mA, 4-20 mA, 0-5 V, 1-5 V, and ±10 V Inputs
•Large Dual-Line 6-Digit Display, 0.60" & 0.46"
•Sunlight Readable Display Models
•NEMA 4X, IP65 Front
•Universal 85-265 VAC, or 12/24 VDC Input Power Models
•Isolated 24 VDC @ 200 mA Transmitter Power Supply
•Programmable Display & Function Keys
•32-Point, Square Root, or Exponential Linearization
•Multi-Pump Alternation Control
•2 or 4 Relays + Isolated 4-20 mA Output Options
•External 4-Relay & Digital I/O Expansion Modules
•USB, RS-232 & RS-485 Serial Communication Options
•Modbus® RTU Communication Protocol Standard
•Free MeterView® Pro Software for Operation, Monitoring, and Programming
F133 Dispenser with 2 Transistor Outputs and External Start/Stop Function
Dispenser with 2 Transistor Outputs and External Start/Stop Function
Description: Delivery Controller
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits for actual total and Eleven 0.31″ (8 mm) for preset total
Case: IP67/NEMA 4X
The F133 is a unique product as it is especially
designed for a controlled delivery of undefined
quantities. It offers all the functionality known
from gas stations to fill-up your car. The unit
incorporates special functions with delay times
to start a pump first, control a valve and expect
a flow within a certain period of time.
Moreover, the flow rate and the allowed total
dispensed quantity is monitored as well.
If, for whatever reason, no pulses are coming
in, the delivery will be terminated after a
pre-defined time. Sub-deliveries are also catered
for allowing you to fill up several compartments
within one and the same delivery. A wide
selection of options further enhance this models
capabilities, including Intrinsic Safety and full
Modbus communication.
F127 Differential Flow computer with Temperature Compensation and 4-20 mA Output
Differential Flow computer with Temperature Compensation and 4-20 mA Output
Description: Differential Flow Computers
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal
Temperature Inputs: PT100- 2 or 3 wire, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits for resettable total and Eleven 0.31″ (8 mm) digits for accum total
Case: IP67/NEMA 4X
The flowcomputer Model F127 has been
developed to calculate corrected differential
liquid volume at normal conditions for generic
products. A typical application is the measurement
of fuel consumption by engines for power
generators, e.g. on board ships and locomotives.
The usual difficulties encountered in such
applications include: pulsating flows, very low
consumption readings, vibration and high
ambient temperatures. These are all well catered
for in the design and operation of the F127.
The corrected volumetric flow in each line is
calculated using the thermal expansion
coefficient algorithm stored in the flowcomputer.
The reference temperature can be defined as
desired, e.g. 15°C, 20°C or 60°F
F126 Flow Computer with Temperature and Pressure Compensation For Corrected Liquid
Flow Computer with Temperature and Pressure Compensation For Corrected Liquid
Description: Flow Computers
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal, 4-20 mA, 0-10 VDC
Outputs: 4-20 mA/0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits for resettable total and Eleven 0.31″ (8 mm) digits for accum total
Case: IP67/NEMA 4X
The flowcomputer Model F126-EG has been
developed to calculate the gas volume at
normal conditions for generic products, in most
cases at 0°C (32 °F) and 1.013 Bar. If desired,
any other temperature or pressure can be set.
The corrected volumetric flow is calculated
using the equations stored in the flowcomputer
while a compressibility factor can be set to
approach a real gas behaviour. A wide selection
of options further enhance this models
capabilities, including Intrinsic Safety and full
Modbus communication.