PJ Boner Automation Services
Calibration, Weighing & Instrumentation Specialists Ireland

Fluidwell

F010 Flow Rate Indicator

F010: Flow Rate Indicator
Description: Flow Rate Indicator
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Six digits 1.0″ x 3.50″ digits (26 mm) LCD
Case: IP67/NEMA 4X

Additional DescriptionMore Details

The F010 is a local indicator to display the
actual flow rate. The measuring and time unit
to be displayed are simply selected through an
alfa-numerical configuration menu. No adhesive
labels have to be put on the outside of the
enclosure: a weather proof and user friendly
solution!
The configuration of K-factors or Span and
number of decimals is done through software
functions, without any sensitive dip-switches or
trimmers. A wide selection of options further
enhance this models capabilities, including
Intrinsic Safety for hazardous area application

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F114 Ratio Indicator with 2 High or Low Alarm Outputs

F114: Ratio Indicator with 2 High or Low Alarm Outputs
Description: Ratio Monitor
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal, 4-20 mA, 0-10 VDC
Outputs: Three Alarm outputs and 4-20 mA/0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Calculates ratio between flow A and B.
• Displays ratio, flow rate A and B and total A
and B (resettable).
• 4 alarm values can be entered: low-low, low,
high and high-high ratio alarm.
• Large 17mm (0.67″) digits.
• Analog output acc. ratio, flow rate A or flow
rate B.
• Very compact design for panel mount,
wall mount or field mount applications.
• Operational temperature -30°C up to +80°C
(-22°F up to 178°F).
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe
II 1 GD EEx ia IIB/IIC T4 T100°C.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Full Modbus communication RS232/485/TTL.
• Loop or battery powered, 8 – 24V AC / DC or
115 – 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F030 Basic Batch Controller with One Output

F030: Basic Batch Controller with One Output
Description: Batch Controller
Inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave, Active pulse signal, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits for resettable total and Eleven 0.31″ (8 mm) digits for accum total
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Large display shows preset value and running
batch value simultaneously.
• Self-learning overrun correction.
• Easy operation to enter a batch value and to
control the process.
• Count-up and count-down function available.
• Selectable on-screen engineering units;
volumetric or mass.
• Ability to process all types of flowmeter
signals.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Rugged aluminum field mount enclosure
IP67/NEMA4X.
• Intrinsically Safe – ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• LED backlight option.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F040 Basic Temperature Indicator

F040:
Description: Temperature Indicator
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: 5½ 0.67″ (26 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays actual temperature and measuring
unit.
• Very large 26mm (1″) digits.
• Piegraph indication: ten segments.
• Number of digits for temperature: 5 1/2.
• Selectable on-screen engineering units: °C-°F-K.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Auto backup of all settings.
• Rugged aluminum field mount enclosure
IP67/NEMA4X.
• Intrinsically Safe – ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• LED backlight option.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F043 Basic Temperature Indicator one High or Low Alarm Output

F043: Basic Temperature Indicator one High or Low Alarm Output
Description: Temperature Monitor
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Outputs: One configurable alarm
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays actual temperature and alarm values.
• Two alarm values can be entered: low and
high temperature alarm.
• Large 17mm (0.67″) digits.
• Selectable on-screen engineering units: °C-°F-K.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Red flashing LED backlight in case of a
temperature alarm.
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe – ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm signal output.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F143 Temperature indicator with 2 High or Low Alarms and a 4-20 mA Output

F143: Temperature indicator with 2 High or Low Alarms and a 4-20 mA Output
Description: Temperature Monitor
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Outputs: Four configurable alarms, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

• Displays actual temperature and alarm values.
• 4 alarm values can be entered: low-low, low,
high and high-high temperature alarm.
• Large 17mm (0.67″) digits.
• Selectable on-screen engineering units
°C – °F – K
• Operational temperature -30°C up to +80°C
(-22°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe
II 1 GD EEx ia IIB/IIC T4 T100°C.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm and analog signal outputs.
• Full Modbus communication RS232/485/TTL.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F050 Basic Pressure Indicator

F050: Basic Pressure Indicator
Description: Pressure Indicator
Pressure Inputs: 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: 5½ 1.0″ (26 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays actual pressure and measuring unit.
• Very large 26mm (1″) digits.
• Piegraph indication: ten segments.
• Number of digits for pressure: 5 1/2.
• Selectable on-screen engineering units:
mBar – Bar – PSI.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Auto backup of all settings.
• Rugged aluminum field mount enclosure
IP67/NEMA4X.
• Intrinsically Safe – ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• LED backlight option.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F053 Pressure Indicator with one High or Low Alarm

F053: Pressure Indicator with one High or Low Alarm
Description: Pressure Monitor
Pressure Inputs: 4-20 mA, 0-10 VDC
Outputs: One configurable alarm
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays actual pressure and alarm values.
• Two alarm values can be entered: low and
high pressure alarm.
• Large 17mm (0.67″) digits.
• Selectable on-screen engineering units:
mBar – Bar – PSI.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Red flashing LED backlight in case of a
pressure alarm.
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe – ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm signal output.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F151 Dual Pressure Indicator

F151: Dual Pressure Indicator
Description: Dual Input Pressure Indicator
Pressure Inputs: 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays for both inputs the actual pressure.
• Large 17mm (0.67″) digits.
• Selectable on-screen engineering units for
each input individually.
• Ability to process (0)4 – 20mA or 0 – 10V
signals.
• Auto backup of all settings.
• Operational temperature -30°C up to +80°C
(-22°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67/NEMA4X.
• Intrinsically Safe
II 1 GD EEx ia IIB/IIC T4 T100°C.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Full Modbus communication RS232/485/TTL.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

F153 Pressure Indicator with 2 High or Low Alarms and 4-20 mA Output

F153: Pressure Indicator with 2 High or Low Alarms and 4-20 mA Output
Description: Dual Pressure Monitor
Pressure Inputs: 4-20 mA, 0-10 VDC
Outputs: One configurable alarm
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X

Additional DescriptionMore Details

Displays actual pressure and alarm values.
• 4 alarm values can be entered: low-low, low,
high and high-high pressure alarm.
• Large 17mm (0.67″) digits.
• Selectable on-screen engineering units
mbar, bar, PSI or no unit.
• Operational temperature -30°C up to +80°C
(-22°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe
II 1 GD EEx ia IIB/IIC T4 T100°C.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm and analog signal outputs.
• Full Modbus communication RS232/485/TTL.
• Loop or battery powered, 8 – 24V AC/DC or
115 – 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.

Download Product Data Sheet


€0.00Price: