PJ Boner Automation Services
Calibration, Weighing & Instrumentation Specialists Ireland

Kimo

HM50 Humidity transmitter

Humidity transmitter

Additional DescriptionMore Details

• Humidity transmitter type HM 50
• Range 0-100 %RH
• 0-10 V output, active sensor, power supply 24 Vac/Vdc (3-4 wires) or 4 -20 mA output, passive loop, power supply 18 to 30 Vdc (2 wires)
• ABS IP 30 housing, without display
• Quick and easy mounting with the “ ¼ turn” system with wall-mount plate

Measuring range……………………………0 to 100 %RH
Unit of measurement……………………..% RH
Response time………………………………1/e(63%) 4 s
Type of fluid ………………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

TM50 Temperature transmitter

Temperature transmitter

Additional DescriptionMore Details

• Temperature transmitter type TM 50/51
• Pt100 3 wires output or Pt1000 2 wires (according to the model)
• ABS IP65 and IP 30 housing, without display
• Quick and easy mounting “1/4 turn” system with wall-mount plate

Measuring range………………………-20 to +80°C (air tight and duct mount model)
+10 à +40°C (ambient model)
Accuracy………………………………..Pt100 class A as per DIN IEC751
Pt1000 class A as per DIN IEC751
Response time…………………………1/e (63%) 5 sec. (ambient model) 1/e (63%) 20 sec. (air tigth model) depending on the probe (Pt100 on terminal block)
Type of fluid…………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

CTV100 Temperature and air velocity transmitter

Temperature and air velocity transmitter

Additional DescriptionMore Details

• Temperature and air velocity transmitter type CTV100.
• Ranges from 0-5 m/s to 0-30 m/s and 0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to
+100°C (see “Configuration”)
• 0-10 V or 4-20 mA output, active, power supply 24 Vac/Vdc (3-4 wires)
• ABS IP 65 housing, with or without display
• Alternating display of air velocity and temperature
• Quick and easy mounting “1/4 turn” system with wall-mount plate

Air Velocity
Measuring range ………………0 to 5m/s,0 to 10m/s, 0 to 15m/s, 0 to 20m/s, 0 to 30m/s
Units of measurement ………m/s and fpm
Accuracy * ……………………….±3% of reading ±0,3 m/s
Response time …………………1/e (63%) 2 sec.
Resolution ……………………….0,1 m/s
Type of fluid……………………..air and neutral gases

Temperature
Measuring range……………………………..0 to +50°C, -20 to +80°C,-50 to +50°C,0 to +100°C
Units of measurement …………………..°C, °F
Accuracy * ……………………………………±0,5% of reading ±0,4°C
Response time ……………………………..1/e (63%) 5 sec.
Resolution ……………………………………0,1°C
Type of sensor………………………………Pt100 class A as per DIN IEC751
Type of fluid………………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

TG100 Temperature Transmitter

Temperature Transmitter

Additional DescriptionMore Details

• Duct temperature transmitter, TG100 type
• Measuring ranges from 0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to +100°C,
0 to 200°C, 0 to +300°C, 0 to +400°C (according to model, see “Configuration”)
• 0-10 V output , active sensor, power supply 24 Vac/Vdc (3-4 wires) or
4-20 mA output , passive loop, power supply 18 to 30 Vdc (2 wires)
• ABS IP 65 housing, with or without display
• Quick and easy mounting “1/4 turn” system with wall-mount plate

Measuring range ………………….see chart ”Configuration”
Units of measurement ………….°C, °F
Accuracy * …………………………..±0,5% of reading ±0,4°C (duct mount probe)
according to the probe (Pt 100 on terminal block)
Response time …………………….1/e (63%) 5 sec. (duct mount probe)
according to the probe (Pt 100 on terminal block)
Resolution …………………………..0,1°C
Type of sensor……………………..Pt 100 class A as per DIN IEC751
Type of fluid………………………. air et neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

TM100 Temperature Transmitter

Temperature Transmitter

Additional DescriptionMore Details

• Temperature transmitter type TM100.
• Measuring ranges from 0 to +50°C, -20 to +80°C, -50 to +50°C,
0 to 100°C (see “Configuration”)
• 0-10 V or 4-20 mA output, active sensor, power supply 24 Vac/Vdc (3-4 wires)
or 4-20 mA output , passive loop, power supply 18 to 30 Vdc (2 wires).
• ABS IP 65 and IP 30 housing, with or without display.
• Quick and easy mounting “1/4 turn” system on wall-mount plate.

Measuring range …………………………….0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to +100°C
Units of measurement …………………..°C, °F
Accuracy * ……………………………………±0,5% of reading ±0,4°C
Response time ……………………………..1/e (63%) 5 sec. (ambient)
1/e (63%) 20 sec. (air tight)
Resolution ……………………………………0,1°C
Type of sensor………………………………Pt 100 class A as per DIN IEC751
Type of fluid………………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

CTV200 Air Velocity / Airflow Transmitter

Air Velocity / Airflow Transmitter

Additional DescriptionMore Details

• Ranges from 0-1 m/s to 0-20 m/s (configurable) and 0-50 °C
• Configurable intermediate ranges
• Airflow function
• Simultaneous display of 2 parameters
• 2 outputs 4-20 mA or 0-10V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer) alarms
• Output diagnostics
• ABS IP 65 housing, with or without 2-line backlit display
• Quick and easy mounting using the “1/4 turn” system with wall-mounting plate.

Air Velocity
Measuring range ………………0-1 m/s to 0-20 m/s
Units of measurement ………m/s, fpm
Accuracy * ……………………….from 0 to 3 m/s : ±3% of reading ±0,03 m/s
from 3 to 20 m/s : ±3% of reading ±0,1 m/s
Response time …………………1/e (63%) 4 sec.
Resolution ……………………….from 0 to 3 m/s : 0,01m/s
3 to 20 m/s : 0,1 m/s
Type of fluid……………………..air and neutral filtered gases

Temperature
Measuring range……………………………..0 to +50°C
Units of measurement …………………..°C, °F
Accuracy * ……………………………………±0,5% of reading ±0,3°C
Response time …………………………….. t0,9 = 9 sec. for Vair = 1 m/s
Resolution ……………………………………0,1°C
Type of sensor………………………………Pt100 class A as per DIN IEC751
Type of fluid………………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

TH200 Humidity / Temperature Transmitter

Humidity / Temperature Transmitter

Additional DescriptionMore Details

• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable intermediate ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro system interchangeable probes (PC or Stainless Steel)
• On-site calibration
• Simultaneous display of 2 parameters
• 2 outputs 4-20 mA or 0-10V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer) alarms
• Output diagnostics
• ABS IP 65 housing, with or without 2-line backlit display.
• Quick and easy mounting using the “1/4 turn” system with wall-mounting plate.

Humidity
Measuring range……………………………0 to 100 %RH
Units of measurement……………………%RH
Accuracy*(Repeatability, linearity, hysteresis) ±1,5%RH (from 3 to 98%RH and if 15°C T 25°C)
Temperature dependence………………±0.04 x (T-20)%RH (if T<15°C or T>25°C)
Response time ………………………………<10 sec. (from 10% RH to 80%RH, V =2m/s) air Resolution ...........................................0,1 %RH Factory calibration uncertainty .........±0.88%RH Type of sensor ....................................capacitive Type of fluid.........................................air and neutral gases (high resistance to solvents) Temperature
Measuring range……………………………from -20 to +120°C ( polycarbonate probe)
from -40 to +180°C (st.steel probe)
Units of measurement……………………°C, °F
Accuracy *…………………………………….±0,3% of reading ±0,25°C
Response time……………………………… t = 9 sec. for V = 1 m/s 0,9 air
Resolution…………………………………….0,1°C
Type of sensor………………………………Pt 100 1/3 as per DIN IEC 751
Type of fluid ………………………………….air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

TH300 Humidity / Temperature Transmitter

Humidity / Temperature Transmitter
Class 300 transmitters have 2 analogue outputs which correspond to the first 2 parameters displayed. You can activate 1 or 2 outputs, and for each output, you can choose between humidity, temperature and other functions.

Additional DescriptionMore Details

• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro interchangeable probes (PC or stainless steel)
• On-site calibration
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 2 outputs 4-20 mA (4 wires) or 0-10V, RS 232, 2 RCR relays 6A/230 Vac
• 2 visual alarms (dual color LED) and audible alarm (buzzer – 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• ABS or ALU IP 65 housing, with or without backlit graphic display.
• Quick and easy mounting using “1/4 turn” system with wall-mounting plate.

Humidity
ALU or ABS housing
WITH or WITHOUT display
TH300
remote probe
TH300
standard
• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro interchangeable probes (PC or stainless steel)
• On-site calibration
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 2 outputs 4-20 mA (4 wires) or 0-10V, RS 232, 2 RCR relays 6A/230 Vac
• 2 visual alarms (dual color LED) and audible alarm (buzzer – 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• ABS or ALU IP 65 housing, with or without backlit graphic display.
• Quick and easy mounting using “1/4 turn” system with wall-mounting plate.

Humidity
Measuring range …………………………………0 to 100 % RH
Units of measurement …………………………% RH
Accuracy*(Repeatability, linearity, hysteresis) ……±1,5%RH (from 3 to 98%RH and if 15°C T 25°C)
Temperature dependence ……………………±0.04 x IT-20I%RH (if T<15°C or T>25°C)
Response time ……………………………………<10 sec. (from 10% RH to 80%RH, Vair=2m/s) Resolution .................................................0,1 % RH Factory calibration uncertainty ...............±0.88%RH Type of sensor ..........................................capacitive Type of fluid ...............................................air and neutral gases (high resistance to solvents) Temperature
Measuring range …………………………………from -20 to +120°C (polycarbonate probe)
from -40 to +180°C (stainless steel probe)
Units of measurement …………………………°C, °F
Accuracy * ………………………………………….±0,3% of reading ±0,25°C
Response time …………………………………… t = 9 sec. for V = 1 m/s 0,9 air
Resolution ………………………………………….0,1°C
Type of sensor…………………………………….Pt 100 1/3 selon DIN IEC 751
Type of fluid………………………………………..air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

CPE300 Flush-mount Pressure Transmitter

Flush-mount Pressure Transmitter

Additional DescriptionMore Details

• Ranges from 0/+10 Pa to -1000/+1000 Pa (according to the model)
• Transmitter resolution at 0.1 Pa on CPE 301 (optional)
• Configurable intermediate and centre zero ranges
• Face calibration
• Interchangeable Measuring Sensor (SPI technology)
• Alternating display of 1 to 3 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 4-20 mA (4 wires) or 0-10V output, RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer – 80 dB) alarms
• Output diagnostics
• MODBUS network RS 485 system (optional)
• Front made of brushed stainless steel or white lacquered,
with electroluminescent display

Measuring range ……………………….see “SPI features”
Units of measurement………………..Pa, mmH O, mbar, inWG 2
Accuracy *………………………………..± 0,5% of reading ± 1 Pa
Zero drift …………………………………..none (see “self-calibration”)
Resolution ………………………………..1 Pa – 0,1 mmH2O – 0,01 mbar – 0,01 InWG
Self-calibration………………………….push-button or automatic (configurable)
Type of fluid ……………………………..air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…

CPA300 Pressure Transmitter

Pressure Transmitter
with large electroluminescent display

Additional DescriptionMore Details

• Ranges from 0/+10 Pa to -10 000/+10 000 Pa (according to model)
• Configurable intermediate and centre zero ranges
• Air velocity and airflow functions (optional)
• Interchangeable measuring sensor (SPI technology)
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 2 analogue outputs 4-20 mA (4 wires) or 0-10 V, RS 232,
4 6A/230 Vac RCR relays (for Ref. CPA300)
2 6A/230 Vac RCR relays (for Ref. CPA300HV)
• Audible alarms (buzzer – 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• Multi-directional housing made of ABS V-0 as per UL 94
Part number • Large display 50 x 190 mm

Measuring range ……………………….see “SPI features”
Units of measurement………………..Pa, mmH O, mbar, inWG, mmHG 2
Accuracy *…………………………………±0,5% of reading ±1 Pa (CPA 301/302/303)
±0,5% of reading ±10 Pa (CPA 304)
Zero drift …………………………………..none (see “self-calibration”)
Resolution ……………………………………1 Pa – 0,1 mmH O – 0,01 mbar – 0,01 InWG – 0,01 mmHG 2
Self-calibration ……………………………push-button or automatic (configurable)
Type of fluid………………………………..air and neutral gases

Download Product Data Sheet


€0.00Price:
Loading Updating cart…
Page 1 of 712345Last »
LoadingUpdating…

Copyright © 2014 P.J.Bonner