Digital Indicator
DM3400 Series Smart Digital Indicator
SMART DIGITAL INDICATOR
DM3400 SERIES: DM3410, DM3420, DM3430
Designed without compromise, the DM3400 series uses leading edge technology to accept all commonly used temperature and process inputs
Engineering units are displayed on a high efficiency daylight readable LED display.
The indicators can be used "standalone" or, using the Modbus serial communications, as part of a larger system.
The highly innovative case design features option "pods" which can be installed without dismantling or re-calibration.
Pods include:
Relay Output
Isolated (4 to 20) mA Re-transmission
RS485 Modbus
- Galvanically Isolated Input
- Thermocouple or Pt100 Input - DM3410
- Current or Voltage Input - DM3420
- True RMS Current and Voltmeter - DM3430
- Flexible Configuration using Option "Pods"
- Max / Min display – DM3420
- User Non Linear Feature for Tank Level Applications
- Internal Power Supply for Current Loop Exitation
DM3600 Series Digital Indicator
INTELLIGENT DIGITAL INDICATOR WITH TFML
DM3600 SERIES: DM3600U, DM3600U/01, DM3600A, DM600A/01.
The DM3600 is an intelligent digital panel meter that can accept inputs from a wide variety of sensors and display the signal digitally. In addition, it has the facility to accept up to two option “Pods” which can be either isolated (4 to 20) mA re-transmission or two normally open alarm relays.
The DM3600 is available in two models. The DM3600U which is a universal input panel indicator and the DM3600A, a universal panel indicator with totaliser functions.
All functions are programmable via the integral front panel keys or via the optional RS485 serial communications port using the Modbus protocol. To facilitate integration into a Scada system, an OPC server is available which also interfaces to the MEDACS, smart DIN rail Signal Conditioner product range, seamlessly integrating front and back of panel instruments.
The DM3600 supports TFML (Transfer Function Module Library) i.e. the ability to download custom functionality by means of standard modules available from the web site. This allows pre-written or custom control functions to be quickly and easily incorporated.
The DM3600A totaliser function enables non-volatile storage of the integrated total to be maintained within the unit, even after loss of power. Output options can be selected to operate on Process Variable (PV) or Total.
- Universal Input
- Flow Totaliser Functions
- 6 Digit Display
- Programmable Relay & Current Outputs
- RS485 Serial MODBUS comms
- IP65 Sealed Front
- Internal Power Supply for Loop Exitation
- Custom Software For Your Application Option
- Programmable Via The Front Panel Or Remote PC
- User Non Linear Function For Tank Level Applications
TH100 Temperature and Humidity Transmitter
Temperature and Humidity Transmitter
• Humidity and temperature transmitter type TH100.
• Measuring ranges 0-100%RH and -50 to +50°C, -20 to +80°C,
0 to +50°C, 0 to +100°C (see "Configuration")
• 0-10 V output, active sensor, power supply 24 Vac/Vdc (3-4wires) or
4 -20 mA output, passive loop, power supply 18 to 30 Vdc (2 wires).
• Housing ABS IP 65 with or without display.
• Alternating display of humidity and temperature
• Quick and easy mounting “1/4 turn” system on wall-mount plate.
Measuring range...........................0 to 100 % RH
Unit of measurement....................% RH
Response time..............................1/e (63%) 4 s
Resolution.....................................0,1% RH
Type of fluid ..................................air and neutral gases
TM100 Temperature Transmitter
Temperature Transmitter
• Temperature transmitter type TM100.
• Measuring ranges from 0 to +50°C, -20 to +80°C, -50 to +50°C,
0 to 100°C (see “Configuration”)
• 0-10 V or 4-20 mA output, active sensor, power supply 24 Vac/Vdc (3-4 wires)
or 4-20 mA output , passive loop, power supply 18 to 30 Vdc (2 wires).
• ABS IP 65 and IP 30 housing, with or without display.
• Quick and easy mounting “1/4 turn” system on wall-mount plate.
Measuring range ..................................0 to +50°C, -20 to +80°C, -50 to +50°C, 0 to +100°C
Units of measurement .......................°C, °F
Accuracy * ..........................................±0,5% of reading ±0,4°C
Response time ...................................1/e (63%) 5 sec. (ambient)
1/e (63%) 20 sec. (air tight)
Resolution ..........................................0,1°C
Type of sensor....................................Pt 100 class A as per DIN IEC751
Type of fluid........................................air and neutral gases
TH200 Humidity / Temperature Transmitter
Humidity / Temperature Transmitter
• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable intermediate ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro system interchangeable probes (PC or Stainless Steel)
• On-site calibration
• Simultaneous display of 2 parameters
• 2 outputs 4-20 mA or 0-10V (4 wires), RS 232, 2 RCR relays 6A/230 Vac
• 2 visual (dual color LED) and audible (buzzer) alarms
• Output diagnostics
• ABS IP 65 housing, with or without 2-line backlit display.
• Quick and easy mounting using the “1/4 turn” system with wall-mounting plate.
Humidity
Measuring range.................................0 to 100 %RH
Units of measurement........................%RH
Accuracy*(Repeatability, linearity, hysteresis) ±1,5%RH (from 3 to 98%RH and if 15°C T 25°C)
Temperature dependence..................±0.04 x (T-20)%RH (if T<15°C or T>25°C)
Response time ....................................<10 sec. (from 10% RH to 80%RH, V =2m/s) air
Resolution ...........................................0,1 %RH
Factory calibration uncertainty .........±0.88%RH
Type of sensor ....................................capacitive
Type of fluid.........................................air and neutral gases (high resistance to solvents)
Temperature
Measuring range.................................from -20 to +120°C ( polycarbonate probe)
from -40 to +180°C (st.steel probe)
Units of measurement........................°C, °F
Accuracy *...........................................±0,3% of reading ±0,25°C
Response time.................................... t = 9 sec. for V = 1 m/s 0,9 air
Resolution...........................................0,1°C
Type of sensor....................................Pt 100 1/3 as per DIN IEC 751
Type of fluid ........................................air and neutral gases
TH300 Humidity / Temperature Transmitter
Humidity / Temperature Transmitter
Class 300 transmitters have 2 analogue outputs which correspond to the first 2 parameters displayed. You can activate 1 or 2 outputs, and for each output, you can choose between humidity, temperature and other functions.
• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro interchangeable probes (PC or stainless steel)
• On-site calibration
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 2 outputs 4-20 mA (4 wires) or 0-10V, RS 232, 2 RCR relays 6A/230 Vac
• 2 visual alarms (dual color LED) and audible alarm (buzzer - 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• ABS or ALU IP 65 housing, with or without backlit graphic display.
• Quick and easy mounting using “1/4 turn” system with wall-mounting plate.
Humidity
ALU or ABS housing
WITH or WITHOUT display
TH300
remote probe
TH300
standard
• Ranges from 0-100%RH and -40 to +180°C (probe dependent)
• Configurable ranges
• Functions : relative and absolute humidity, dew point, wet and
dry temperature, enthalpy.
• Smart-Pro interchangeable probes (PC or stainless steel)
• On-site calibration
• Simultaneous display of 1 to 4 parameters
• External transmitter inputs (KIMO Class 200 and 300)
• 2 outputs 4-20 mA (4 wires) or 0-10V, RS 232, 2 RCR relays 6A/230 Vac
• 2 visual alarms (dual color LED) and audible alarm (buzzer - 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• ABS or ALU IP 65 housing, with or without backlit graphic display.
• Quick and easy mounting using “1/4 turn” system with wall-mounting plate.
Humidity
Measuring range .......................................0 to 100 % RH
Units of measurement ..............................% RH
Accuracy*(Repeatability, linearity, hysteresis) ......±1,5%RH (from 3 to 98%RH and if 15°C T 25°C)
Temperature dependence ........................±0.04 x IT-20I%RH (if T<15°C or T>25°C)
Response time ..........................................<10 sec. (from 10% RH to 80%RH, Vair=2m/s)
Resolution .................................................0,1 % RH
Factory calibration uncertainty ...............±0.88%RH
Type of sensor ..........................................capacitive
Type of fluid ...............................................air and neutral gases (high resistance to solvents)
Temperature
Measuring range .......................................from -20 to +120°C (polycarbonate probe)
from -40 to +180°C (stainless steel probe)
Units of measurement ..............................°C, °F
Accuracy * .................................................±0,3% of reading ±0,25°C
Response time .......................................... t = 9 sec. for V = 1 m/s 0,9 air
Resolution .................................................0,1°C
Type of sensor...........................................Pt 100 1/3 selon DIN IEC 751
Type of fluid...............................................air and neutral gases
PD765 Trident Process & Temperature Meter
The Model PD765 Trident digital panel meter is one of the most versatile digital panel meters on the market and will satisfy a wide variety of process applications. The Trident can be field programmed to accept process voltage (0-5V, 1-5V, etc) and current (4-20 mA) inputs, 100 Ohm RTDs, and the four most common thermocouples.
It is housed in a shallow-depth, 1/8 DIN enclosure that features a
NEMA 4X front panel and convenient mounting hardware. There are two power options for the Trident: 85 to 265 VAC or 12-36 VDC and it can provide 24 VDC to power the transmitter if needed. Programming and setup can be performed with the four front panel pushbuttons, free MeterView software, or using the Copy function.
Process Inputs: 0-20 mA, 4-20 mA, 1-5 V, -10 to 10 V
Temperature Inputs: J, K, T, E TC; 100 ? Pt RTD
Display: 0.56" (14 mm) Red LED 4 Digits
Case: 1/8 DIN, High Impact Plastic, Shallow Depth
Power: 85-265 VAC or 12-36 VDC
Test Drive the Trident Meter By Using the Online Virtual Meter Below:
Trident Virtual Meter
PD743 Sabre T Low-Cost Temperature Meter
The Sabre T temperature meter is easily programmed using
the four front panel buttons. There is only one switch on the
entire meter, there are no jumpers, and no need to ever open
the case.
The Sabre T temperature meter is easily programmed usingthe four front panel buttons. There is only one switch on theentire meter, there are no jumpers, and no need to ever openthe case.
Inputs: J, K, T, E TC; 100 ? Pt RTD
Display: 0.56" (14 mm) Red LED 4 Digits
Case: 1/8 DIN, High Impact Plastic, Shallow Depth
Power: 85-265 VAC or 12-36 VDC
THA300 Humidity / Temperature Transmitter
Humidity / Temperature Transmitter
with Large Electroluminescent Display
THA 300 has 2 analogue outputs which corresponds to the 2 parameters displayed. You can activate 1 or 2 outputs and for each output, you can choose between humidity, temperature, Absolute humidity, Dew point, Humid temperature and Enthalpy
• Configurable intermediate ranges
• Functions : relative and absolute humidity, dew point, wet and dry temperature,
enthalpy.
• Smart-Pro interchangeable probes (PC or stainless steel)
• On-site calibration
• Simultaneous display of 1 to 4 parameters
• KIMO external transmitter inputs (Class 200 and 300)
• 2 analogue outputs 4-20 mA (4 wires) or 0-10 V, RS 232,
4 6A/230 Vac RCR relays (for Ref. CPA300)
2 6A/230 Vac RCR relays (for Ref. CPA300HV)
• Audible alarms (buzzer - 80 dB)
• Output diagnostics
• MODBUS network RS 485 system (optional)
• Multi-directional housing made of ABS V-0 as per UL 94
• Large display (50 x 190 mm)
Humidity
Units of measurement ..............................%RH
Accuracy*(Repeatability, linearity, hysteresis)........±1,5%RH (from 3 to 98%RH and if 15°C T 25°C)
Temperature dependence ........................±0.04 x IT-20I%RH (if T<15°C or T>25°C)
Response time ..........................................<10 sec. (from 10%RH to 80%RH, V = 2 m/s) air
Resolution .................................................0,1 %RH
Factory calibration uncertainty...............±0.88%RH
Type of sensor...........................................capacitive
Type of fluid ...............................................air et neutral gases (high resistance to solvents)
Temperature
Measuring range .......................................from -20 to +120°C (Polycarbonate probe)
from -40 to +180°C (st.steel probe)
Units of measurement ..............................°C, °F
Accuracy .................................................± 0,3% of reading ± 0,25°C
Response time .......................................... = 9 sec. for = 1 m/s
Resolution .................................................0,1°C
Type of sensor...........................................Pt 100 1/3 as per DIN IEC751
Type of fluid...............................................air et neutral gases
F143 Temperature indicator with 2 High or Low Alarms and a 4-20 mA Output
F143: Temperature indicator with 2 High or Low Alarms and a 4-20 mA Output
Description: Temperature Monitor
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Outputs: Four configurable alarms, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X
• Displays actual temperature and alarm values.
• 4 alarm values can be entered: low-low, low,
high and high-high temperature alarm.
• Large 17mm (0.67") digits.
• Selectable on-screen engineering units
°C - °F - K
• Operational temperature -30°C up to +80°C
(-22°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe
II 1 GD EEx ia IIB/IIC T4 T100°C.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm and analog signal outputs.
• Full Modbus communication RS232/485/TTL.
• Loop or battery powered, 8 - 24V AC/DC or
115 - 230V AC power supply.
• Sensor supply 3.2 / 8.2 / 12 / 24V DC.
F043 Basic Temperature Indicator one High or Low Alarm Output
F043: Basic Temperature Indicator one High or Low Alarm Output
Description: Temperature Monitor
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Outputs: One configurable alarm
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: Seven 0.67″ (17 mm) digits and Eleven 0.31″ (8 mm) digits
Case: IP67/NEMA 4X
Displays actual temperature and alarm values.
• Two alarm values can be entered: low and
high temperature alarm.
• Large 17mm (0.67") digits.
• Selectable on-screen engineering units: °C-°F-K.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Red flashing LED backlight in case of a
temperature alarm.
• Very compact design for panel mount, wall
mount or field mount applications.
• Rugged aluminum field mount enclosure
IP67 / NEMA4X.
• Intrinsically Safe - ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• Alarm signal output.
• Loop or battery powered, 8 - 24V AC/DC or
115 - 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.
F040 Basic Temperature Indicator
F040:
Description: Temperature Indicator
Inputs: PT100-2 or 3 wire, 4-20 mA, 0-10 VDC
Power Options: 8-24 VAC or VDC, 115-230 VAC
Display: 5½ 0.67″ (26 mm) digits
Case: IP67/NEMA 4X
Displays actual temperature and measuring
unit.
• Very large 26mm (1") digits.
• Piegraph indication: ten segments.
• Number of digits for temperature: 5 1/2.
• Selectable on-screen engineering units: °C-°F-K.
• Operational temperature -40°C up to +80°C
(-40°F up to 178°F).
• Very compact design for panel mount, wall
mount or field mount applications.
• Auto backup of all settings.
• Rugged aluminum field mount enclosure
IP67/NEMA4X.
• Intrinsically Safe - ATEX, IECEx, FM and CSA
approval for gas and dust applications.
• Explosion/flame proof II 2 GD EEx d IIB T5.
• LED backlight option.
• Loop or battery powered, 8 - 24V AC/DC or
115 - 230V AC power supply.
• Sensor supply 8.2 / 12 / 24V DC.
Loading...